Parallel optics moved the industry away from one fibre pair per direction. A 40G or 100G parallel port carries its lanes over one multi fibre connector, 400G and 800G go further with eight or sixteen lanes on a single trunk, and the cable becomes part of the interface rather than an accessory. The module sets the rate and the reach, but the trunk, the connector and the patch plan decide whether the link comes up at all.
So a multi fibre link is quoted as a package: lane count, fibre count, connector polish and polarity, and loss over the whole run. The column behind this page is optical communication products, and the rate families are collected on optics selection guides.
Rate per lane and lane count are fixed by the standards family. 40G runs as four lanes of 10G, 100G as four lanes of 25G, 400G as eight lanes of 50G and 800G as eight lanes of 100G, and each lane needs two fibres. A 400G parallel port therefore consumes eight fibres of a trunk and an 800G parallel port consumes sixteen.
Two consequences follow: the cable and connector type must match the module rather than the rack, and one high rate port can feed several slower ports through a breakout harness, which is how a 400G uplink is usually added without replacing existing 100G equipment.
| Module | Rate | Media / wavelength | Reach class | Where it usually lands |
|---|---|---|---|---|
| 40G QSFP+ SR4 and CSR4 | 40G | MMF, 850 nm parallel | 100 m to 300 m class | Rack rows on twelve fibre trunks |
| 100G QSFP28 SR4 | 100G | MMF, 850 nm, eight fibre | 70 m to 100 m class | Short row links inside a hall |
| 100G QSFP28 PSM4 and CWDM4 | 100G | SMF, 1310 nm parallel or CWDM | 500 m to 2 km class | Building to building runs on single mode |
| 400G QSFP-DD DR4 | 400G | SMF, 1310 nm parallel, eight fibre | 500 m class | Leaf and spine within one hall |
| 400G QSFP-DD 2xFR4 | 400G | SMF, CWDM, two fibre groups | 2 km class | Hall to hall where trunks are already in place |
| 800G OSFP and QSFP-DD DR8 | 800G | SMF, eight lanes, sixteen fibre | 500 m class | Accelerator and leaf ports in a dense row |
| 800G 2xFR4 | 800G | SMF, CWDM over two groups | 2 km class | Fabric exits across a campus |
| MPO and MTP trunks | Per lane | MMF or SMF, 8, 12, 16 or 24 fibre | Per cable grade | Carrying the lanes between patch panels |
| Breakout harnesses | Per lane | Same media as the trunk | Per cable grade | Splitting one port into four or eight slower ports |
Reach classes are the standard ones for each family and the working limit is the measured loss of the trunk. The rate families are listed on the 100G and 400G pages, the high rate side on 800G, and the lane options on CWDM4, PSM4 and DR4.
Three properties of the trunk cause most links that will not come up. Fibre count has to match the module: eight or twelve fibre for 40G and 100G parallel, sixteen or twenty four fibre for 400G and 800G parallel. Polish has to be consistent at both ends, because single mode multi fibre connectors are normally angled and multimode ones normally flat. Polarity has to follow one convention through the whole run, since a trunk wired the wrong way is a dead link rather than a marginal one.
A parallel link has a budget per lane, and the trunk, both mated pairs and every patch point sit inside it. Connector loss class matters more than cable grade once a link crosses a patch panel at each end, so measure per lane rather than on the trunk as a whole, keep the results with the patch schedule, and leave a margin for the patch points that get added later.
Breakouts let one high rate port serve four or eight lower rate ports, which is why they appear in every migration, and they multiply the connector count: check each lower rate port against the module at its far end instead of assuming the high rate budget still applies. Density is the limit that software never shows, because sixteen fibre trunks are stiffer to route than patch cords, so plan the route with the same care as the port list.
Coding follows the platform named on the request: the part is programmed for that switch or server model, tested on it, and it is not manufactured by that brand. Coded parts for the common platforms are collected on the Cisco, Arista and Mellanox pages. Spares are counted per part group, plus one spare trunk and one harness per cable type, because a spare module with no matching trunk is not a spare.
Can a twelve fibre trunk feed a 400G parallel module?
No. A 400G parallel port needs eight lanes, which means sixteen fibres, so use a sixteen or twenty four fibre trunk.
Do both ends have to use the same connector polish?
They should. Angled and flat connectors can be mated in some combinations, but the result is extra loss and reflectance that the budget should not absorb.
Is a breakout harness cheaper than adding modules?
It reuses ports you already own, but count every added mated pair before deciding, because the harness is not free loss.
Can multimode be used at 400G?
Only over a very short class and with matching multimode parallel options. Where the run leaves the row, single mode parallel is the standard answer.
What do you need to quote a cabling and optics package?
The platform models with releases, the port list with rates and form factors, the trunk runs with lengths and connector types, the patch and polarity plan, and the quantity per part with trunks and harnesses on separate lines.
Send the port list with rates, the trunk runs with lengths and connector types, and the patch plan, and we come back with a coded module per port, the trunks and harnesses to match and the spare lines set out separately. Related reading: 800G DR8, FR4 and ZR+, 400G leaf and spine and all optics selection guides.
APEX is a communication technology brand focused on optical transceivers, telecom synchronization products, and network infrastructure equipment. We provide products and engineering support for telecom operators, data centers, mobile networks, and enterprise customers worldwide.
APEX GROUP is headquartered in Hong Kong, with our core team and supply chain operations based in China. We ship to customers across Asia, the Middle East, Europe, Africa, and the Americas.
We are a brand owner with deep engineering partnerships. We control product design, specification, quality validation, and supply chain management. Our products are built to our specifications by qualified manufacturing partners, and we handle all testing, coding, and quality assurance before shipment.
Yes. We code transceivers to match the host platform requirements of major switch and router vendors including Cisco, Juniper, Arista, HPE, Huawei, Nokia, and others. Tell us your platform model and required OS version, and we will ship modules that are recognized natively by your equipment.
Datasheets, compatibility matrices, and S-parameter reports are available for all standard products. Contact our sales team or visit the product pages on our website to request documentation.
Provide us with your switch make, model, and OS version. We code the transceiver firmware accordingly before shipment. If you are testing for the first time, we recommend ordering a sample unit to validate compatibility in your specific environment before placing a volume order.
Switch vendors occasionally introduce transceiver whitelisting in new OS releases. We track major platform updates and can provide recoded firmware matching the new OS requirements. Contact technical support if your existing APEX modules stop being recognized after a switch upgrade.
Contact our sales team by email, WhatsApp, or WeChat with your part number and quantity. We will confirm pricing, lead time, and shipping options. For first-time customers, we typically recommend starting with a sample order to validate compatibility before scaling to production volumes.
We ship via DHL, FedEx, and UPS for express delivery, typically 3-7 business days to most destinations. For volume orders, we also offer air freight and sea freight options. We can ship on your courier account or ours, and we handle all export documentation.
Sample orders start from 1-2 units for evaluation. For production orders, MOQ varies by product type, typically 10-50 units for standard transceivers. Contact us for specific product MOQs.
We accept wire transfer (T/T) as our standard payment method. For established customers, we can offer net-term payment arrangements. Contact our sales team to discuss payment terms.
All APEX products come with a 3-year standard warranty against manufacturing defects. We offer advance replacement for defective units, shipping the replacement before you return the failed unit to minimize downtime. For full details, visit our After-Sales Service page.
Contact us by email, WhatsApp, or WeChat. Describe your issue with as much detail as possible, including switch model, OS version, transceiver part number, and the problem you are seeing. Our support engineers will respond within one business day.
Yes, we strongly encourage sample testing. Order 1-2 units of each model you plan to deploy. Test them in your switches with your fiber plant and traffic load. Once validated, we can proceed with production quantities.
Yes. Many of our customers are telecom operators and government networks requiring 5-10 year supply continuity. We offer lifecycle management commitments with advance notification of any changes. See our Global Supply Chain page for details on long-term supply programs.