An AI data centre is not one building with one fabric. Training clusters are built out in halls, a campus grows around them, and the links between halls, buildings and nearby sites carry the traffic that keeps the cluster working as one machine: checkpointing, storage replication, model distribution and east-west traffic between pods.
That mix sets the requirement. Ports in the back-end fabric have moved to 400G and 800G per port, hall-to-hall links need kilometres of reach without coherent cost, and campus or metro interconnect between sites is where coherent optics come in. The selection question is therefore about distance tiers first, then form factor, then fibre and cooling.
800G on one port raises the number of switch ports a fabric can use for the same rack unit count, which is what matters when a cluster needs a large number of high-rate endpoints in a small cabling distance. QSFP-DD and OSFP both carry 800G; the choice between them is usually decided by the switch side and by whether the port has to break out later.
| Module | Rate | Media / wavelength | Reach | Typical use |
|---|---|---|---|---|
| 800G OSFP / QSFP-DD DR8 | 800G, 8 x 100G | SMF, parallel 1310 nm | 500 m class | In-row and same-hall links between switches in the back-end fabric |
| 800G OSFP / QSFP-DD 2xFR4 | 800G, 2 x 400G | SMF, CWDM or LAN-WDM | 2 km class | Hall-to-hall links where a duplex pair is available |
| 800G OSFP 2xSR4 / SR8 | 800G | MMF, 850 nm parallel | 50 to 100 m | Short in-row links where structured MMF already exists |
| 800G to 2 x 400G breakout | 800G host, 2 x 400G links | SMF or MMF plus breakout assembly | Span dependent | Feeding two 400G ports from one 800G cage |
| 400G QSFP-DD DR4 / FR4 | 400G | SMF, parallel or CWDM | 500 m to 2 km | Fabric tiers still running at 400G per port |
| 400G / 800G ZR and ZR+ coherent | 400G or 800G coherent | DWDM C-band, tunable | Campus to metro spans | Building-to-building and site-to-site links without grey reach |
| DAC and AEC assemblies | 400G / 800G | Copper, passive or active | A few metres | Adjacent racks where copper is sufficient |
The reach column lists the standard classes behind each code; the working limit is the cabling loss and the connector count on the actual route. The 800G form factors and reach codes are set out on the 800G transceiver page, the tier below on the 400G QSFP-DD and OSFP page, and the coherent side on coherent optics.
Treat the interconnect as tiers. In-row and same-hall links are hundreds of metres at most and are served by parallel single-mode or multimode parts, DR8 or SR8 types, where the cabling is short and the port count is high. Hall-to-hall and building-to-building links move to the 2 km class, usually 2xFR4 optics on a duplex pair or a parallel single-mode part. Campus and metro links between sites are where coherent plugs in: a 400G or 800G ZR or ZR+ module on the DWDM grid carries the span without a transponder shelf at each end. State the tier for every link in the request, since the reach code and the fibre type follow from it.
An 800G parallel port normally terminates on an MPO or MTP assembly, and that is where build-outs go wrong. Trunk polarity and the pin-out of each cassette have to match the transmit-to-receive mapping of the port. Order the optics and the cabling assemblies as one set, keep the polarity scheme consistent across the hall, and check the link length against the reach class after the patch panels and cassettes are counted, not before.
An 800G module dissipates well above a 400G module in the same cage family, and the back-end fabric concentrates many of them per rack unit. Three checks belong before the count is fixed: the port power budget of the line card, the airflow available in the rack, and whether coherent modules are being mixed into the same shelf. Where thermal margin is tight, spreading high-rate ports across several line cards is more forgiving than concentrating them on one.
The module has to be supported by the host port and coded for the platform you name, with optical power, module temperature and alarms readable through the host. Modules supplied for branded switches are compatible parts and are not manufactured by the brand of the host, with no claim of relationship to that brand. Name the platform and firmware release, and say whether the far end will be a different vendor, since that decides the coding and the mode set. Platforms common in these fabrics include Mellanox, Arista, Cisco and Juniper platforms. Keep spares per link type: a failed optic in a training fabric costs cluster time, not one link.
Is 800G needed for AI interconnect, or is 400G enough?
It depends on the tier and the switch. 400G remains the working rate one tier down; 800G is chosen where panel density and port count per rack unit are the limit, which is typical at the top of a back-end fabric.
QSFP-DD or OSFP for an 800G link?
Both carry 800G. The switch port decides, and the second question is whether the cage has to break out to two 400G links later.
When do I need coherent optics between buildings?
When the span is longer than the grey reach class of the tier, or when fibre is scarce enough that several links have to share one pair on the DWDM grid. A 400G or 800G ZR or ZR+ module then replaces the transponder shelf.
Can existing multimode cabling be reused at 800G?
Only for the short in-row class where an SR-type parallel module is specified and the installed fibre grade supports the rate and distance. Hall-to-hall and longer links are normally single-mode.
What has to be in the request for an interconnect build?
The tier and measured route length, the switch platform and firmware, the port type and breakout plan, the fibre and cabling assemblies available, and the temperature and power limits of the cabinet.
Send the switch platform, the tier and measured distance, the port type and the cabling available, and we confirm the reach code, the form factor and the coding for each link. Related reading: 800G DCO transponder card where capacity has to be aggregated onto wavelengths, 400G transponder and muxponder cards for shelf-based transport, and all optics selection guides.
APEX is a communication technology brand focused on optical transceivers, telecom synchronization products, and network infrastructure equipment. We provide products and engineering support for telecom operators, data centers, mobile networks, and enterprise customers worldwide.
APEX GROUP is headquartered in Hong Kong, with our core team and supply chain operations based in China. We ship to customers across Asia, the Middle East, Europe, Africa, and the Americas.
We are a brand owner with deep engineering partnerships. We control product design, specification, quality validation, and supply chain management. Our products are built to our specifications by qualified manufacturing partners, and we handle all testing, coding, and quality assurance before shipment.
Yes. We code transceivers to match the host platform requirements of major switch and router vendors including Cisco, Juniper, Arista, HPE, Huawei, Nokia, and others. Tell us your platform model and required OS version, and we will ship modules that are recognized natively by your equipment.
Datasheets, compatibility matrices, and S-parameter reports are available for all standard products. Contact our sales team or visit the product pages on our website to request documentation.
Provide us with your switch make, model, and OS version. We code the transceiver firmware accordingly before shipment. If you are testing for the first time, we recommend ordering a sample unit to validate compatibility in your specific environment before placing a volume order.
Switch vendors occasionally introduce transceiver whitelisting in new OS releases. We track major platform updates and can provide recoded firmware matching the new OS requirements. Contact technical support if your existing APEX modules stop being recognized after a switch upgrade.
Contact our sales team by email, WhatsApp, or WeChat with your part number and quantity. We will confirm pricing, lead time, and shipping options. For first-time customers, we typically recommend starting with a sample order to validate compatibility before scaling to production volumes.
We ship via DHL, FedEx, and UPS for express delivery, typically 3-7 business days to most destinations. For volume orders, we also offer air freight and sea freight options. We can ship on your courier account or ours, and we handle all export documentation.
Sample orders start from 1-2 units for evaluation. For production orders, MOQ varies by product type, typically 10-50 units for standard transceivers. Contact us for specific product MOQs.
We accept wire transfer (T/T) as our standard payment method. For established customers, we can offer net-term payment arrangements. Contact our sales team to discuss payment terms.
All APEX products come with a 3-year standard warranty against manufacturing defects. We offer advance replacement for defective units, shipping the replacement before you return the failed unit to minimize downtime. For full details, visit our After-Sales Service page.
Contact us by email, WhatsApp, or WeChat. Describe your issue with as much detail as possible, including switch model, OS version, transceiver part number, and the problem you are seeing. Our support engineers will respond within one business day.
Yes, we strongly encourage sample testing. Order 1-2 units of each model you plan to deploy. Test them in your switches with your fiber plant and traffic load. Once validated, we can proceed with production quantities.
Yes. Many of our customers are telecom operators and government networks requiring 5-10 year supply continuity. We offer lifecycle management commitments with advance notification of any changes. See our Global Supply Chain page for details on long-term supply programs.