AI/ML Cluster Optics 800G: Optics Selection Guide


What is different about an AI/ML cluster fabric
A training cluster is not a general purpose network with more bandwidth bolted on. The back-end fabric connects accelerators to each other, the traffic

What is different about an AI/ML cluster fabric

A training cluster is not a general purpose network with more bandwidth bolted on. The back-end fabric connects accelerators to each other, the traffic is collective, and one slow or flapping link slows the whole job rather than one conversation. That is why the fabric is built as a flat, high radix topology with a fixed number of links per node, and why the optics in it are chosen once and then kept uniform.

This guide covers the optical links inside that fabric: node to leaf, leaf to spine, and the storage and management networks alongside them. Links that leave the building are covered on the 800G AI data centre interconnect guide.

Why 800G ports sit at the top of the cluster

Two forces push a cluster to 800G per port. The first is the link count: an accelerator server with several network ports multiplies into a fabric where every leaf port matters, so a higher rate per port keeps the switch count, the rack unit count and the cable volume down. The second is the switch side: a fixed number of cages per chassis is filled with the fastest port the fabric will carry for the life of the cluster, and the tier behind it can then break out to lower rates.

Uniformity matters more here than in a best effort network, because a training job is sensitive to link flaps and to any asymmetry in the path. A mixed inventory of modules of unknown age and unknown coding is usually where that uniformity is lost.

Recommended optics inside a training cluster

Link in the clusterModuleRateMedia / wavelengthReach class
Node to leaf, same rackDAC or AEC assembly400G / 800GCopper, passive or activeA few metres
Node to leaf, same row800G SR8 or SR4 parallel800GMMF, 850 nm parallel50 to 100 m
Node to leaf, single-mode plant800G DR8800G, 8 x 100GSMF, parallel 1310 nm500 m class
Leaf to spine, same hall800G DR8800G, 8 x 100GSMF, parallel 1310 nm500 m class
Leaf to spine, hall to hall800G 2xFR4800G, 2 x 400GSMF, CWDM or LAN-WDM2 km class
Storage and front-end network400G QSFP-DD DR4 / FR4400GSMF, parallel or CWDM500 m to 2 km
Campus or metro extension400G / 800G ZR and ZR+ coherent400G or 800GSMF, DWDM C-band tunableCampus to metro

The reach column lists the standard classes behind each code; the working limit is the measured loss after patch panels and cassettes. Form factors and reach codes are on the 800G transceiver page, the tier below on the 400G QSFP-DD and OSFP page, and the coherent side on coherent optics.

Copper, active cable or optics: the first decision in the rack

Inside a rack, copper is the cheapest and lowest power connection, so DAC assemblies stay first choice for the shortest runs. Once a link crosses more than a rack or two, reach, bend radius and cable volume work against copper: a heavy bundle of trunks in front of the ports blocks airflow and makes the rack hard to service. Active electrical cables cover runs that are too long for passive copper but too short to justify optics, and optics take over where the run leaves the row or crosses a hall. Fix that break point by distance and airflow, and put it in the cabling plan at the start.

FEC, latency and lossless behaviour

Collective traffic over remote direct memory access is lossless and latency sensitive, which puts two requirements on the optical layer. The forward error correction profile has to be the same at both ends and along the whole path, because a mismatch shows up as a link that comes up but never carries the job at full rate. The latency class and mode set then have to match what the switch and the network interface expect, which is why the firmware release belongs in the request. Keep one rate per path as well: a 400G link inside an 800G path costs more in fault finding than the module it saved.

Coding, firmware and spares in a cluster

The optics have to be supported by the host port, coded for the platform you name, and readable through it, so that power, temperature and alarms can be watched from the switch. Optics supplied for branded switches are compatible parts coded for the platform you name, tested against the port, and are not manufactured by the brand of the host. Name the platform, the firmware release and the rate mode, and say whether the far end will be a different vendor, since that decides the coding. Platforms common in these fabrics include Mellanox, Arista, Cisco and Juniper. Hold spares per link type and per rate: a training fabric goes down on the type it cannot replace that day.

How to choose, in order

  1. Fix the topology first: links per node, leaf and spine radix, and the rate of each tier.
  2. Decide copper, active cable or optics by distance and airflow, rack by rack.
  3. Choose the reach code per tier against measured route length, including patch panels and cassettes.
  4. Keep one rate per path and one FEC profile from end to end.
  5. Check rack power, cooling and panel density before the port count is fixed.
  6. Name the platform and firmware for coding, and hold spares per link type and per rate.

Frequently asked questions

Is copper still usable in an 800G cluster?
Yes, for short in-rack runs. Passive copper is first choice to the top of rack, active electrical cables cover the longer in-row runs, and optics take over once the link leaves the row.

Which 800G module goes between leaf and spine?
DR8 for the 500 m parallel class inside a hall, and 2xFR4 for the 2 km class where a duplex pair already exists between halls. The switch port and the cabling decide.

Does a cluster need industrial temperature optics?
Not for the grade itself, since the equipment sits in a conditioned hall. Airflow matters instead: a high density rack with poor airflow runs its optics hot, so module temperature has to be readable through the switch.

Can a cluster mix vendors at the two ends of a link?
Usually yes, when each end is coded for its own host and the rate, FEC and mode set match. Say in the request that the far end is a different platform, because that decides the coding.

What has to be in the request for a cluster build?
The topology and links per node, the rate per tier, the measured runs, the switch platform and firmware, the cabling available, and the power and airflow limits of each rack.

Send the topology, the rate per tier, the measured runs and the switch platform and firmware, and we confirm the module, the reach code and the coding for each link type. Related reading: the AI training cluster DWDM interconnect page for wavelength level capacity, the 400G to 800G migration guide for a staged refresh, and all optics selection guides.