APEX

APEX 1300W Titanium Server Power Supply
APEX 1300W Titanium Server Power Supply
Home > Server Power Supplies > Server Power Supplies > APEX 1300W Titanium Server Power Supply

APEX 1300W Titanium Server Power Supply

Product Features
APEX 1300W Titanium Server Power Supply1U hot-pluggable, N+1 redundant, PMBus-enabled PSU for enterprise servers and edge data centers. Titanium efficiency with cold redundancy and in-system firmware

Parameters

Detailed Introduction

APEX 1300W Titanium Server Power Supply


1U hot-pluggable, N+1 redundant, PMBus-enabled PSU for enterprise servers and edge data centers. Titanium efficiency with cold redundancy and in-system firmware management.


Product Overview

The APEX 1300W Titanium is a 1U, hot-pluggable server power supply engineered for enterprise server platforms, edge data centers, and converged infrastructure. Delivering 1300W of output with 80Plus Titanium efficiency, it features the same advanced digital management as the 2000W model — PMBus 1.2 telemetry, cold redundancy, in-system firmware update, and black box fault recording — in a cost-optimized 1300W power envelope ideal for mainstream deployment.

1300W

MAX OUTPUT

96%

PEAK EFFICIENCY

1U

FORM FACTOR

Titanium

80PLUS RATING


Key Specifications

Input
Voltage Range (AC)90–264 VAC (100–240 V nominal)
Voltage Range (DC)180–320 VDC
Frequency47–63 Hz
Max Current≤6.5 A @ 100 VAC
Inrush Current≤ 35 A (cold start, peak)
Power Factor>0.90 @ 10% / >0.96 @ 20% / >0.98 @ 50% / >0.99 @ 100%
Hold-up Time≥11 ms @ 70% load / ≥70 ms (+12Vsb)
Input ConnectorIEC 320 C-20, 16A/250VAC
Output
Main Rail+12 V, 108 A (1300 W max)
Standby Rail+12 Vsb, 3 A (36 W max)
Voltage Regulation+12 V: ±5%
Ripple & Noise≤ 120 mVp-p
Efficiency (80Plus Titanium)
10% Load≥ 90%
20% Load≥ 94%
50% Load≥ 96%
100% Load≥ 91%
Protection
OCP / OVP / UVP / SCP / OTPFull protection suite on all rails

Advanced Features


PMBus 1.2 Digital Monitoring

Real-time input/output telemetry. STATUS commands with SMBAlert# fault signaling. PEC error checking per SMBus 2.0.


Cold Redundancy

CR_BUS inter-PSU communication. Dynamic standby/wake based on load. 1+1, 2+2, 3+1 configurations. Load-share threshold optimization per slot position.


In-System FW Update

Boot loader + main program dual-bank. BMC-driven update via PMBus. Bad-image recovery guaranteed.


Black Box Fault Recording

NV event log: PMBus snapshot, system tracking data, real-time clock at fault. Accessible via 12Vsb — no AC required.


FRU EEPROM

IPMI 1.0 compliant. Manufacturer, model, serial, power ratings. Multi-record area for DC output and PSU info.


Environmental

Operating: 0–50 °C. Storage: –40 to +70 °C. Humidity: 5–95% RH. Altitude: up to 5000 m.